The H-Factor

Reducing Entropy

Recent Posts

Welcome

Recently our previous blog service (Typepad) ended their business – so, we have a new home. It will take a bit to get images back and displaying properly, but we are working on it! Final pageview count of original Typepad blog: 387,232

Using a Non-Standard Pipe Type in HydraCALC

A customer called today asking how to enter a 1″ black plastic underground pipe for the calc. This particular situation sounded unique enough that I did not tell him to add that pipe type to our database, as I would have if he expected to see this pipe type used repeatedly. I told him to…

Using the Hydratec Software Download Area

Hydratec uses ShareFile to distribute our software installs and updates. New customers, or those without access, must request access to be able to get at these downloads. Access is only available to customers with a Hydratec subscription or those on an update plan. You can access the download area and request access by picking the…

May 2010
M T W T F S S
 12
3456789
10111213141516
17181920212223
24252627282930
31  

This is the second in a series of posts on how to self-diagnose errors
you may encounter while elevating your drawing to 3D or while running
AutoCalc or AutoList. HydraCAD includes a number of tools to assist you
with the diagnosis and correction of these errors, and these post will
review some of them.

Sometimes when you AutoCalc only some of your pipes actually make it to HydraCALC, or you get an error that prevents you from loading the job into HydraCALC. Both of these can be traced back to a problem with how your pipes are connected.

 The drawing below would not calculate for a customer:

P1

They got the following error when the AutoCalc process handed the job off to HydraCALC:

Failed

Here is how we diagnosed the problem:

1. We started the AutoCalc Process (SAC)…

Acsetup

2. …and picked the Check Model button. This analyzes the piping system starting at the supply and proceeding as far as it can. When complete, this highlights all the flowing pipe using dark blue polylines, starting at the supply. The problem area becomes apparent immediately:

P2

The dark blue pline doesn't make it very far. After we zoomed into the end of it, we were able to see an unusual piping arrangement that was to blame for the problem. Once that was reconfigured, we started the process again and picked Check Model again and all of the piping was traced in blue this time.

Using the Check Model button is similar to the old View Flowing Pipes and Paths feature in V45 and earlier versions of HydraCAD. Try is next time, problem or no.

Posted in

Leave a comment